Average daylight factor

2.4%

Adequate daylight

Window-to-floor ratio19%Rule of thumb ≥ 15–20% for habitable rooms
Limiting depth (BRE)6 m ≥ room depth · OK
Visible sky angle θ75°
15°limiting depth 6 minoutdepth = 6 mSECTION · ADF 2.4% · HEAD 2.4 M · DRAG ↕whole room within limiting depthinoutwidth = 4 mdepth = 6 mPLAN · WINDOW 3 M WIDE

Wind-driven (cross)

Airflow450 L/s
Air changes24.1 ACH
Opening for 5 ACH0.12 m²

Q = Cv · A · v (ASHRAE Fundamentals). Cross-ventilate rooms up to ≈ 14 m deep (5 × H).

Stack-driven

Airflow282 L/s
Air changes15.1 ACH
Opening for 5 ACH0.13 m²

Q = Cd · A · √(2gΔH·ΔT/Ti), Cd 0.65. Single-sided ventilation works to ≈ 7 m deep (2.5 × H, CIBSE AM10).

Early-stage estimates. Use climate-based daylight modelling and ventilation/overheating simulation for design stage.